GSW Office FR
A single-glazed system of fireproof walls
A single-glazed system meeting the requirements of the binding fire legislation. Sound insulation parameters permitting comfortable, efficient work.
Download the product card
Select the product version
Product features
| Approvals, tests etc. |
|
| Category of use | IV |
| Category of space | A, B, C, D, E |
| Type of glass | Pyrobel 16VL, 16 EG VL, 25 VL |
| Max height (mm) | 3000 |
| Acoustic insulation | RW 38 ÷ 42 dB / RA1 37 ÷ 40 dB |
| Materials and finishes | Anodized aluminum / Aluminum RAL |
| Approval document | ETA-18/1097 |
| Glass | Rw [dB] | C [dB] | RA1 [dB] |
|---|---|---|---|
| AGC Pyrobel 16 VL | 38 | -1 | 37 |
| AGC Pyrobel 16 EG VL | 40 | -1 | 39 |
| AGC Pyrobel 16 EG Stratophone VL | 41 | -1 | 40 |
| AGC Pyrobel 25 VL | 42 | -2 | 40 |
| Glass | Rw [dB] | C [dB] | RA1 [dB] |
|---|---|---|---|
| Vetrotech Contraflam Structure Lite 30 | 38 | -2 | 36 |
| Vetrotech Contraflam Structure 30 | 40 | -2 | 38 |
| Vetrotech Contraflam Structure 30 Silence | 42 | -1 | 41 |
| Glass | Rw [dB] | C [dB] | RA1 [dB] |
|---|---|---|---|
| Vetrotech Contraflam 30 | 39 | -1 | 38 |
| Vetrotech Contraflam 30 Silence | 41 | -1 | 40 |
| AGC Pyrobel 16 | 40 | -1 | 39 |
| AGC Pyrobel 16 EG Stratophone | 41 | -1 | 40 |
| Glass | Fire resistance |
|---|---|
| AGC Pyrobel 16 VL | EI 30 |
| AGC Pyrobel 16 EG VL | EI 30 |
| AGC Pyrobel 16 EG Stratophone VL | EI 30 |
| AGC Pyrobel 25 VL | EI 60 |
| Glass | Fire resistance |
|---|---|
| Vetrotech Contraflam Structure Lite 30 | EI 15 |
| Vetrotech Contraflam Structure 30 | EI 30 |
| Vetrotech Contraflam Structure 30 Silence | EI 30 |
| Glass | Fire resistance |
|---|---|
| Vetrotech Contraflam 30 | EI 30 |
| Vetrotech Contraflam 30 Silence | EI 30 |
| AGC Pyrobel 16 | EI 30 |
| AGC Pyrobel 16 EG Stratophone | EI 30 |
Alu E2/C-0 silver anod.
Alu E2/C-35 black anod.
RAL 9005S
Alu E2 inox anod. polished
Alu RAL/special anod.
Alu RAL
Alu E2/C-0 silver anod.
Alu E2/C-35 black anod.
RAL 9005S
Alu E2 inox anod. polished
Alu RAL/special anod.
Alu RAL
Alu E2/C-0 silver anod.
Alu E2/C-35 black anod.
RAL 9005S
Alu E2 inox anod. polished
Alu RAL/special anod.
Alu RAL
Characteristics
GSW Office FR is a single-glazed system – without muntins and with grids, meeting the requirements of applicable fire regulations, as well as the acoustic insulation of office rooms.
Depending on the type of glass used, the walls may have fire resistance ranging from EI 15 to EI 60. The necessity to use fire-resistant glass does not mean giving up on acoustic parameters – all glazing variants in the GSW Office FR system have been subjected to laboratory tests, which confirmed the high parameters airborne sound insulation – RW up to 42 dB.